Dedicated RDMA (SR-IOV InfiniBand)¶
This page describes the recommended practice of providing dedicated RDMA resources for Pods through SR-IOV in InfiniBand Fabric scenarios.
Scope of Application¶
- Applies only to InfiniBand networks
- AI/HPC scenarios that require high performance, low latency, and strong isolation
- Depends on the IB Fabric and Subnet Manager
Prerequisites¶
- The InfiniBand Fabric is deployed in the cluster and the Subnet Manager (such as OpenSM) works properly
- The RDMA NIC supports SR-IOV and VFs are enabled
- The RDMA subsystem is in exclusive mode
- Spiderpool is installed (refer to Install Spiderpool)
Architecture¶
flowchart LR
subgraph K8s["Kubernetes / DCE"]
API[K8s API]
Spiderpool[Spiderpool IPAM]
Multus[Multus]
SriovOp[SR-IOV Operator]
SriovDP[SR-IOV Device Plugin]
IbCNI[IB-SRIOV CNI]
end
subgraph Node["RDMA Node"]
Pod[AI Pod]
SriovCNI[SR-IOV CNI]
VF[VF -IB]
PF[PF NIC]
end
API --> Spiderpool
API --> SriovOp --> SriovDP
Pod --> Multus --> SriovCNI --> VF --> Fabric[InfiniBand Fabric]
Spiderpool --> Multus
IbCNI --> SriovCNI
PF --> VF Configuration Steps¶
0. Offline/Addon preparation (recommended)¶
In offline environments, it is recommended to prepare the Spiderpool Addon offline package first, and then perform the installation and upgrade.
1. Host preparation (exclusive mode)¶
Set the exclusive mode and enable SR-IOV VFs on the RDMA node:
2. Install and enable IB SR-IOV components¶
The following are recommended when installing Spiderpool:
- Sriov-Operator (used to install the SR-IOV CNI and device plugin)
- IB-SRIOV CNI (for InfiniBand scenarios)
Key parameter recommendations:
| Parameter | Recommended Value | Description |
|---|---|---|
| SriovOperator.install | true | Enable the SR-IOV Operator |
| sriovDevicePlugin.resourceName | rdma_ib_sriov | SR-IOV resource name |
| ibSriovCni.install | true | Enable the IB-SRIOV CNI |
3. Configure the SR-IOV node policy¶
Create an SR-IOV node policy for the IB NIC to define the VFs and resource names. Refer to SR-IOV Node Policy.
4. Create the Multus configuration¶
Create a Multus configuration for the IB network. Refer to Manage Multus CR.
5. Create an IP pool¶
Create an IPPool based on the service network segment. Refer to Create Subnet and IP Pool.
6. Create a workload¶
Bind the IB resources and network configuration as needed to ensure that the Pod obtains the expected IB resources.
Verification¶
- Whether the Pod has obtained the expected Underlay IP
- Whether the IB device and RDMA resources are visible inside the Pod
- Whether the Subnet Manager works stably
Example:
kubectl get sriovnetworknodepolicy -n kube-system
kubectl get node -o json | jq -r '[.items[] | {name:.metadata.name, rdma:.status.allocatable}]'
O&M Recommendations¶
- View RDMA metrics: RDMA Metrics
- Use the visualization dashboard: RDMA Dashboard
Notes¶
- IB scenarios have higher requirements on hardware and the network environment
- Avoid mixing with the shared RDMA plugin