Skip to content

KubeVirt Fixed IP and Underlay Network

This page describes the recommended configuration for using Spiderpool in DCE to provide fixed IP and Underlay network capabilities for KubeVirt virtual machines.

Scenarios

  • KubeVirt virtual machines need to keep the same IP after restart, rebuild, or live migration
  • VMs need to be directly connected to the Underlay network

Differences Between Network Modes and Capabilities

Mode Typical CNI NIC Count Service Mesh Live Migration Description
passt macvlan/ipvlan Single NIC Supported Not supported Suitable for lightweight scenarios
bridge ovs-cni Multiple NICs Not supported Not supported Suitable for multi-NIC scenarios

Note: Spiderpool records the fixed IP of a KubeVirt VM at the VM level rather than the Pod level.

Prerequisites

  • Spiderpool is installed (refer to Install Spiderpool)
  • An Underlay CNI is ready (Macvlan/IPvlan or OVS)

Key Configuration

Spiderpool enables the KubeVirt fixed IP feature by default. To disable it, set the following when installing Spiderpool:

  • ipam.enableKubevirtStaticIP=false

Example Procedure (passthrough + macvlan)

  1. Create the Multus configuration for macvlan (refer to Manage Multus CR).
  2. Create an IPPool (refer to Create Subnet and IP Pool).
  3. Create a VM and specify the default NIC configuration:
metadata:
  annotations:
    v1.multus-cni.io/default-network: kube-system/macvlan-ens192

After creation, the VM Pod keeps obtaining the same IP across restart and rebuild scenarios.

Note

  • In the KubeVirt live migration scenario, Spiderpool does not perform IP conflict detection
  • The passt mode supports only a single NIC; the bridge mode supports multiple NICs but does not support Service Mesh