VXLAN Performance

EgressGateway utilizes VXLAN tunnels, which typically introduce an approximate 10% performance loss. If you observe that EgressGateway performance is below expectations, follow these steps for troubleshooting:

1. Verify Node-to-Node Throughput

The network speed between host nodes should be as expected. VXLAN performance depends on the host NIC offload settings.

  • NIC Offloading: The offload settings of the host network interface impact VXLAN performance slightly (in 10G network tests, the difference is about 0.5 Gbits/sec).
  • Enable Offloading: Run the following command on the host to enable offloading:

    ethtool --offload <host-interface-name> rx on tx on
    

2. Verify VXLAN Offload Settings

VXLAN interface offload settings can significantly impact performance.

  • In 10G network tests, VXLAN throughput was:
  • Without checksum offload: 2.5 Gbits/sec
  • With checksum offload: 8.9 Gbits/sec
  • Check VXLAN checksum offload status with:

    ethtool -k egress.vxlan
    
  • If offload is disabled, enable it by setting the following Helm values:

    feature:
      vxlan:
        disableChecksumOffload: false
    

Performance Benchmark

Physical Server Benchmark

Test Environment:

Name CPU Memory Network Interface
Node 1 Intel(R) Xeon(R) E5-2680 v4 @ 2.40GHz 128GB 10G Mellanox
Node 2 Intel(R) Xeon(R) E5-2680 v4 @ 2.40GHz 128GB 10G Mellanox
Target Intel(R) Xeon(R) E5-2680 v4 @ 2.40GHz 128GB 10G Mellanox
Test Case Scenario Throughput
Case 1 Node → Node 9.44 Gbits/sec (send) - 9.41 Gbits/sec (receive)
Case 2 Egress VXLAN → Egress VXLAN 9.11 Gbits/sec (send) - 9.09 Gbits/sec (receive)
Case 3 Pod → Egress Node → Target 9.01 Gbits/sec (send) - 8.98 Gbits/sec (receive)

egress-check

Virtual Machine Benchmark (VMware)

Test Environment:

  • VMware virtual machines with 4 vCPUs and 8GB RAM
Name CPU Memory Network Interface
Node 1 Intel(R) Xeon(R) Gold 5118 @ 2.30GHz (4C) 8GB VMXNET3
Node 2 Intel(R) Xeon(R) Gold 5118 @ 2.30GHz (4C) 8GB VMXNET3
Target Intel(R) Xeon(R) Gold 5118 @ 2.30GHz (4C) 8GB VMXNET3
Test Case Scenario Throughput
Case 1 Node → Node 2.99 Gbits/sec (send) - 2.99 Gbits/sec (receive)
Case 2 Egress VXLAN → Egress VXLAN 1.73 Gbits/sec (send) - 1.71 Gbits/sec (receive)
Case 3 Pod → Egress Node → Target 1.23 Gbits/sec (send) - 1.22 Gbits/sec (receive)

Key Observations

  • Physical servers provide near 90%+ efficiency even with VXLAN.
  • VMware VMs show significant performance degradation in VXLAN due to virtualization overhead.
  • Enabling checksum offload improves VXLAN performance significantly.

For best performance:

  • Ensure host NIC offload settings are optimized
  • Enable VXLAN checksum offload via Helm values
  • Use physical servers where high throughput is required